Vadodara, Gujarat
GST No. 24AARFN5355N1ZL
Call 08047676102 92% Response Rate
Minimum Order Quantity: 1 Piece
Product Brochure
Material | Stainless Steel |
Usage/Application | Automotive |
Model Name/Number | Tf |
Application Media | Water |
Display | Local |
Operating Temperature | 40 |
Flow Range | 20 |
Line Size | 1/2" |
Power Supply | 230 |
Size | 1/2" |
Accuracy | 2% |
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Model Name/Number | MTRM |
Brand | NRG GLOBAL |
Usage/Application | Industrial |
Range Ability | 0-50000 lph |
Tube Body Construction | Stainless Steel |
Float Material | SS316 |
Flow rate | 0-50000 LPH |
Scale Length | DIAL TYPE |
Power Supply | NA |
Line Size | 1" TO 4" |
NRG GLOBAL MAKE Metal Variable Area Type Flow Meter are designed to measure flow rate of liquids and gases under
critical conditions. It consists of a tapered metal tube, an indicating assembly and float. A magnet
encapsulated in float couples with rotating magnets are connected to an indicating pointer. Henceforth,
the movement of the float is accurately indicated in terms of flowrate.
They are intended for application where high pressure, temperature or corrosive conditions preclude
the use of conventional glass tube. These are all Metal Variable Area Type Flow meter design to measure
flow rate of Liquids & Gases under critical conditions. It consists of a tapered metal tube, an indicating
assembly and a float. A magnet encapsulates in float couples with rotating magnets connected to an
indicating pointer, thus the movement of the float, is accurately indicated in terms of flow rate.
2. Working Principle
When fluid or gas flows through a taper tube containing a float, a pressure difference of P1 and P2 is
created between upper and lower side of the float. The float moves upwards by a force obtained by
multiplying the pressure differential by the maximum cross-sectional area of the float.
Based on Bemoulli's theorem, the principle mentioned above can be theoretically expressed as
follows. Due to taper tube, as the float moves upwards, the fluid passing area increases as a result of which the
differential pressure decreases. Upward movement of float stops when the dead load is dynamically balanced by the differential pressure. Tapering of metering tube is so designed that the vertical movement of the float becomes linearly proportional to the rate of flow and the scale is provided to read the position of the float, thus
giving birth to flow rate indication.